3.3.2 Writing a project to the programmable controller
3 CREATING PROGRAM IN STRUCTURED LADDER/FBD LANGUAGE
GX Works2
3.3.2 Writing a project to the programmable controller
Write the project data to the programmable controller CPU set as the connection destination in Section
3.3.1.
1. Select "Online" "Write to PLC" to display the
Online Data Operation screen.
You can click (Write to PLC) to display the Online
Data Operation screen.
2. Set the "Target module" and "Target project" on
the Online Data Operation screen.
After the setting, click the button.
Setting of the target module
Target module: Select <<PLC Module>>
Setting of the project
Symbolic Information : Select "Program Memory/Device Memory" in "Target Memory", and
check "Symbolic Information" in "Target".
"Program (Program File)" and "MAIN" are checked in "PLC Data", and
change into gray.
"Symbolic Information" contains program files and variables.
PLC Data : Select "Program Memory/Device Memory" in "Target Memory", and
check "PLC/Network/Remote Password/Switch Setting" in "Target". Do
not check "Global Device Comment" or "Device Memory".
Click it.
Setting of the project
Setting of the target module
(To the next page)